Test & Commissioning.

Acceptance tests from workshop to field (FAT, SAT) and commissioning — delivery with certified report.

Test; It is the moment when engineering design confronts field reality. Hydroport carries out this facing with standard protocols: FAT, SAT, performance testing and certification.

What do we offer in this service?

  • FAT — Factory Acceptance Test, 1.5x pressure in the workshop
  • SAT — Site Acceptance Test, actual load on site under
  • Leakage test (helium monitoring optional)
  • Performance test (pressure-flow characteristic)
  • Certified report + production book
[ SCOPE OF SERVICE ]

Test types.

01

FAT — Factory Acceptance

1.5x working pressure + tightness + function test in the workshop; customer testimony.

02

SAT — Site Acceptance

Performance + safety testing under real load after assembly in the field.

03

Performance Test

Pump pressure-flow characteristic, cylinder speed profile, valve response time.

04

Periodic Retest

Annual mandatory pressure control (PED compliance) and certification renewal.

[ PROCESS ]

don't work with you
Our form.

5 steps from first phone call to guaranteed delivery. Transparent, measurable and with engineering discipline.

  1. 01

    Needs Analysis

    We start with field survey, line conditions and existing system breakdown.

  2. 02

    Solution Design

    We prepare technical file with circuit diagram, hydraulic calculation and BOM.

  3. 03

    Offer & Approval

    We offer transparent item-by-item offer, deadline and payment plan.

  4. 04

    Application

    Manufacturing in our own facility, delivery with assembly and testing in the field.

  5. 05

    Maintenance & Support

    Periodic maintenance contract and 7/24 emergency service. We have your back with.

[ CAPABILITY ]

Test equipment park.

EquipmentSpec
Hydraulic test bench700 bar × 200 L/min, 4 line output
Data loggerHMG 4000 (8 channel pressure + 4 temperature)
Leak tightness testHelium leak detector (10⁻⁹ mbar·L/s)
TemperatureK-type thermocouple + IR (FLIR)
Flow meterTurbine + gear flowmeter (certified)
AccreditationCalibration from TÜRKAK accredited laboratory
[ REFERENCE ]

Field stories.

Railroad

IRIS compatible FAT

Workshop acceptance tests of 30 locomotive set on tram hydraulic brake test bench; The certificate file was submitted to UNIFE.

Defense

Helium sealing

Military vehicle hydraulic system helium leak test; The certificate is in MIL-STD-810 standard.

[ FAQ ]

Frequently asked questions.

Is customer-witnessed testing possible?

Yes. FAT is compulsorily witnessed in the workshop; SAT customer + Hydroport engineer together on site.

Are your certificates valid internationally?

Our test equipment is calibrated by TÜRKAK accredited laboratory; Our reports are written in EN/ISO standards and are valid in the EU.

Is periodic PED testing mandatory?

Annual testing is a legal requirement for systems that fall into the pressure equipment category. Hydroport gives this test within the scope of the contract.

[ CONTACT ]

Let's prepare for the certified test.

Let's write the test protocol together; Let's create a schedule for FAT and SAT.

TEKLİF AL